Skip to content
Internet

Nas Calculator

Nas Calculator

See how much usable storage your NAS really gives you. Enter your drives, their size, and the RAID level to get capacity, efficiency, and fault tolerance.

Capacity of each drive in terabytes. Decimals are allowed, e.g. 3.5.

RAID 5 needs 3+ drives, RAID 6 needs 4+, RAID 10 needs 4+ in an even number, and RAID 1 needs exactly 2 drives.

Four 4 TB drives do not always give you 16 TB of storage. Depending on the RAID level you choose, the same four drives can give you anywhere from 4 TB to the full 16 TB — because every level trades some capacity for speed or protection against drive failure. The Nas Calculator above removes the guesswork. Enter how many drives you have, the size of each drive, and the RAID level, and it shows the usable capacity you will actually get, how efficiently your raw space is being used, how much is lost to redundancy, and how many drives can fail without losing your data.

What Is a NAS RAID Calculator?

A NAS, or network-attached storage, is a small box of hard drives on your home or office network that stores everyone’s files, photos, videos, and backups in one place. RAID — redundant array of independent disks — is the system that decides how data is spread across those drives. Different RAID levels divide the job differently: some stripe data across every drive for maximum speed and capacity, some mirror everything for maximum safety, and some store parity information so a failed drive can be rebuilt. The usable capacity depends entirely on which level you pick. This calculator works with generic RAID levels rather than any one brand’s setup wizard: RAID 0, RAID 1, RAID 5, RAID 6, RAID 10, and JBOD. It assumes all drives are the same size, which is the recommended setup, and reports theoretical capacity — your real NAS will reserve a little space for its own system software.

How to Use the Nas Calculator

Enter the number of drives first — the whole number of physical drives in your NAS. Next, enter the capacity of each drive in terabytes; decimals are fine, so a 3.5 TB drive is entered as 3.5. Then choose the RAID level from the dropdown. Press Calculate and the headline number shows your usable capacity in terabytes. The breakdown lines explain it: the RAID level you chose, the raw capacity (drives times size), the storage efficiency (usable capacity as a percentage of raw capacity), the amount lost to redundancy (parity or mirrors), and the number of drive failures the array can survive. If your drive count does not satisfy the chosen level’s minimum — for example two drives with RAID 5 — the calculator explains the rule instead of showing a wrong number.

The RAID Capacity Formulas Explained

Every RAID level has its own simple formula, where n is the number of drives and S is the size of each drive. RAID 0 stripes data across all drives with no redundancy: usable = n × S, efficiency 100 percent, and zero drives can fail. JBOD, or “just a bunch of disks,” spans them end to end with the same math: usable = n × S, 100 percent efficiency, zero fault tolerance. RAID 1 mirrors one drive onto the other: usable = S, efficiency 50 percent with two drives, and one drive can fail. RAID 5 spreads parity across all drives: usable = (n − 1) × S, one drive can fail, and it needs at least three drives. RAID 6 uses double parity: usable = (n − 2) × S, two drives can fail, and it needs at least four drives. RAID 10 stripes across mirrored pairs: usable = (n ÷ 2) × S, efficiency 50 percent, needs at least four drives in an even number, and it survives at least one failure — specifically one failed drive per mirror pair. Storage efficiency is simply usable capacity divided by raw capacity, times 100. The “lost to redundancy” line is raw minus usable: the price of protection, measured in terabytes.

Worked Examples

Example one. Four 4 TB drives in RAID 5. Step one, raw capacity is 4 × 4 = 16.00 TB. Step two, the RAID 5 formula gives usable capacity of (4 − 1) × 4 = 12.00 TB. Step three, storage efficiency is 12 ÷ 16 × 100 = 75.0 percent. Step four, lost to redundancy is 16.00 − 12.00 = 4.00 TB — exactly one drive’s worth of parity. Step five, fault tolerance is 1 drive: any single drive can die and your data is rebuilt from the parity on the rest. This is the classic home-NAS setup, and the calculator shows all five lines exactly as computed here.

Example two. Six 8 TB drives in RAID 6. Step one, raw capacity is 6 × 8 = 48.00 TB. Step two, the RAID 6 formula gives (6 − 2) × 8 = 32.00 TB usable. Step three, efficiency is 32 ÷ 48 × 100 = 66.7 percent. Step four, lost to redundancy is 48.00 − 32.00 = 16.00 TB, two drives’ worth of double parity. Step five, the array survives 2 simultaneous drive failures. RAID 6 costs more capacity than RAID 5, but during a long rebuild of a big modern drive, a second failure is a real risk — the extra parity is insurance, and the calculator prices it at 16 TB.

Example three. Two 4 TB drives in RAID 1. Step one, raw capacity is 2 × 4 = 8.00 TB. Step two, mirroring means usable capacity equals one drive: 4.00 TB. Step three, efficiency is 4 ÷ 8 × 100 = 50.0 percent. Step four, lost to redundancy is 8.00 − 4.00 = 4.00 TB. Step five, one drive can fail with zero data loss — the surviving drive is an exact copy. This is the simplest safe two-bay setup, and it shows the fundamental trade of mirroring: half your space buys complete peace of mind.

Example four. Eight 10 TB drives in RAID 10. Step one, raw capacity is 8 × 10 = 80.00 TB. Step two, the RAID 10 formula gives (8 ÷ 2) × 10 = 40.00 TB usable. Step three, efficiency is 40 ÷ 80 × 100 = 50.0 percent. Step four, lost to redundancy is 40.00 TB. Step five, the array survives at least 1 drive failure — one per mirrored pair, so up to four failures if they land in different pairs, but two failures in the same pair would be fatal. RAID 10 is the performance choice: rebuilds are fast because they just copy a mirror, at the cost of half your capacity.

Example five. Three 6 TB drives in RAID 0. Step one, raw capacity is 3 × 6 = 18.00 TB. Step two, striping gives the full 18.00 TB usable. Step three, efficiency is 100.0 percent. Step four, lost to redundancy is 0.00 TB. Step five, survivable failures: none. One dead drive destroys the whole array. The calculator shows this starkly on purpose: RAID 0 is for speed on scratch data you can afford to lose, never for anything irreplaceable.

How to Interpret Your Result

The headline number is your usable capacity — the storage your NAS will actually offer you for files. Compare it with the raw capacity line to feel the cost of your RAID choice in real terabytes. Storage efficiency tells you what share of the drives you bought is working for you; anything under 100 percent is the price of redundancy or mirroring. The “lost to redundancy” line converts that price into terabytes, which is often more vivid than a percentage: losing 16 TB to RAID 6 parity feels different from losing 4 TB to RAID 5. The fault-tolerance line is the other half of the deal — it tells you how many drives can die at once without data loss. Read these together: a level is only “worth it” if its capacity cost buys you a failure tolerance you actually need. Finally, remember the calculator assumes identical drives; with mixed sizes, most systems treat every drive as the size of the smallest one, so a 4 TB drive paired with an 8 TB drive wastes half the bigger drive.

Choosing the Right RAID Level

For most home users with three or four bays, RAID 5 is the sweet spot: 75 percent efficiency at four drives, one-drive protection, and cheap expansion. If your drives are very large — 8 TB and up — consider RAID 6, because rebuilding a huge drive takes many hours and the risk of a second failure during that window is real; the extra drive of parity is worth it. RAID 1 suits two-bay boxes perfectly: simple, fast to rebuild, and 50 percent efficiency is a fair price for two drives. RAID 10 belongs to users who need performance — video editors, virtual machines, busy small-business file shares — and can afford to give up half their capacity for fast rebuilds and speed. RAID 0 and JBOD have one legitimate home: temporary or easily replaced data, like a video-editing scratch disk, where speed matters and loss does not. And whatever level you choose, internalize the golden rule the calculator’s note states plainly: RAID is not a backup. It protects against drive failure, not against theft, fire, accidental deletion, or ransomware. Keep a real backup elsewhere.

Common Mistakes to Avoid

The biggest mistake is buying drives and assuming you get the sum of their sizes — as the examples show, RAID 5 with four 4 TB drives gives 12 TB, not 16, and RAID 1 with two drives gives half. The second mistake is mixing drive sizes and expecting full capacity; the array will be limited by the smallest drive, so matched drives are always the better buy. The third mistake is choosing RAID 0 for precious data because the capacity number looks attractive — one failure ends everything. The fourth mistake is forgetting that rebuilds take time and stress the remaining drives, which is why large-drive arrays should lean toward RAID 6. The fifth mistake is confusing terabytes with tebibytes: drive makers sell decimal terabytes (1 TB = 1,000 GB), while operating systems often display binary tebibytes, so your NAS may show slightly less than the calculator’s headline number — that is normal and expected. The sixth mistake is skipping the backup because “RAID protects me.” It protects against exactly one thing: dead drives. Protect against everything else separately.

Frequently Asked Questions

1. What does a NAS RAID calculator do?

It converts your drive count, drive size, and RAID level into the usable storage you will actually get, plus efficiency and fault tolerance. It answers the question “how much space will I really have” before you buy drives or build the array.

2. Why is usable capacity less than the sum of my drives?

Because RAID levels reserve space for parity data or full mirror copies. That reserved space is what lets the array survive drive failures and rebuild, so it is protection you are buying, not space being wasted.

3. What is the difference between RAID 5 and RAID 6?

RAID 5 stores one drive’s worth of parity and survives one failure; usable capacity is (n − 1) × size. RAID 6 stores two drives’ worth of parity and survives two failures; usable capacity is (n − 2) × size. RAID 6 needs at least four drives.

4. How many drives does RAID 10 need?

At least four, and the count must be even, because RAID 10 builds mirrored pairs and then stripes across them. With four drives you get the capacity of two; with eight, the capacity of four.

5. Can I use different-sized drives in RAID?

You can, but most systems treat every drive as the size of the smallest one. A 4 TB and an 8 TB drive in RAID 1 give you 4 TB usable and waste 4 TB. Matched drives are strongly recommended, and this calculator assumes them.

6. What does JBOD mean?

JBOD stands for “just a bunch of disks.” It joins drives end to end into one volume with no striping benefit and no redundancy. Usable capacity is the full sum of the drives, and any single failure loses at least that drive’s data.

7. Is RAID a backup?

No. RAID protects against drive failure only. It does not protect against accidental deletion, ransomware, fire, theft, or a failed NAS unit itself. Keep a separate backup of anything you cannot afford to lose.

8. Why does my NAS show less space than the calculator?

Two reasons. First, the NAS reserves some space for its operating system. Second, drive makers count a terabyte as 1,000 gigabytes while systems often display tebibytes of 1,024 gibibytes, so reported numbers look slightly smaller. Both are normal.

9. Which RAID level is best for a home NAS?

For three or four bays, RAID 5 is the usual answer: good efficiency with one-drive protection. With very large drives, RAID 6 is safer. For two bays, RAID 1. There is no universal best — it depends on your bay count and how much you fear downtime.

10. What happens when a drive fails in RAID 5?

The array keeps running in a degraded state using parity data, and you replace the dead drive with a new one. The NAS then rebuilds the missing data onto the replacement, which can take many hours on large drives. Back up first if you can.

11. Can I expand a RAID array later?

Often yes: many NAS systems let you add a drive and expand the volume, or replace drives one by one with larger ones. The process is slow and stresses the array, so run it only with a current backup in place.

12. What is storage efficiency?

Usable capacity divided by raw capacity, as a percentage. RAID 0 and JBOD are 100 percent efficient, RAID 5 with four drives is 75 percent, and mirroring levels are 50 percent. It measures how much of your purchased space holds your data.

13. Does RAID make my NAS faster?

RAID 0 and RAID 10 can improve read and write speeds by working across multiple drives at once. Parity levels like RAID 5 and RAID 6 can be slower at writes because every write must update parity. For a home network, the network itself is usually the bottleneck anyway.

14. Why does RAID 1 need exactly 2 drives in this calculator?

Classic RAID 1 is a simple mirror of one drive onto one other drive. Some systems support multi-way mirrors with more drives, but the standard two-drive mirror is what this calculator models, and it is what nearly all two-bay NAS units use.

15. Should I use RAID 0 for anything?

Only for data you can lose without pain: video-editing scratch disks, game libraries you can re-download, or temporary processing space. Never for photos, documents, or anything irreplaceable — one failure destroys the entire array.

Final Thoughts

Your NAS is only as good as the RAID level behind it. The Nas Calculator turns drive shopping from guesswork into arithmetic: pick a level, and see the usable terabytes, the efficiency, the redundancy cost, and the failures you can survive before you spend a cent. For most homes the answer will be RAID 5 or RAID 6, with matched drives and — always — a real backup somewhere else. Run your numbers, choose the protection you actually need, and fill those bays with confidence.